Routine Maintenance of Chemical Pumps


Published:

Mar 07,2024

In the daily use of chemical pumps, daily maintenance of chemical pumps must be done to continuously extend their service life and improve work efficiency.

Routine Maintenance of Chemical Pumps

In the daily use of chemical pumps, daily maintenance of chemical pumps must be done to continuously extend their service life and improve work efficiency.

1. During the actual operation of the chemical pump, the lubricating oil required for the operation of the chemical pump must be replaced in time. Within the first month of use, the specific replacement frequency of the lubricating oil should be controlled at about 100 hours. After that, the lubricating oil can be gradually slowed down. The replacement frequency is approximately once after 500 operating hours. The temperature of the bearing cannot exceed the ambient temperature by 35 degrees Celsius, and the highest temperature should be less than 80 degrees Celsius.
 
2. Do a good job in preventing dripping in the packing chamber. In order to avoid or reduce the dripping phenomenon in the packing chamber of the chemical pump to a certain extent, the relevant managers and staff of the chemical pump operation need to regularly optimize and adjust the packing gland. , to ensure the functioning of the capping function.
 
3. Chemical pump maintenance personnel need to conduct regular inspections of the actual wear of the chemical pump shaft sleeve. When it is found that the wear of the chemical pump shaft sleeve is relatively large, effective measures should be taken to promptly maintain or replace it. Pay great attention to the changes in indoor and outdoor temperatures during the use of chemical pumps. For example, when using chemical pumps when the temperature is relatively low in winter, staff need to thoroughly clean the water inside the chemical pump in time after the chemical pump stops running. Clean it thoroughly to prevent the chemical pump from freezing and cracking to the greatest extent, and to ensure the service life of the chemical pump to a certain extent.
 
4. When the chemical pump has been out of use for a relatively long time, comprehensive maintenance of the chemical pump needs to be done. If the chemical pump is stored for too long without taking scientific maintenance measures, a series of operational problems will occur. Therefore, the staff must be proficient in the correct disassembly and assembly steps of the chemical pump. When the chemical pump is stopped, the chemical pump can be removed. The body is effectively disassembled in accordance with standardized operating procedures, and the moisture inside the chemical pump is wiped clean, and then special grease is evenly applied to the joint and rotating parts of the chemical pump, and proper storage is carried out to fundamentally ensure the safety of the chemical pump when it is used again. normal operation.

Keyword:

Chemical Pump